<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 08:27:24 +0000</lastBuildDate>
    <item>
      <title>bdu:2023-02904</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2023-02904</link>
      <description>bdu:2023-02904</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2023-02904</guid>
    </item>
    <item>
      <title>certfr-2022-avi-017 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Certaines d'entre elles permettent à un at…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-017</link>
      <description>certfr-2022-avi-017</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-017</guid>
    </item>
    <item>
      <title>EUVD-2026-322756</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-322756</link>
      <description>EUVD-2026-322756</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-322756</guid>
    </item>
    <item>
      <title>fkie_cve-2021-29241</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-29241</link>
      <description>&lt;p&gt;CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-29241</guid>
    </item>
    <item>
      <title>FSA-202202 — Festo: Controller CECC-S,LK,D family &lt;= 2.3.8.1 - multiple vulnerabilities in CODESYS V3 runtime system</title>
      <link>https://cve.radiocsirt.org/vuln/fsa-202202</link>
      <description>&lt;p&gt;The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fsa-202202</guid>
    </item>
    <item>
      <title>GHSA-2hc4-qjj9-7p6r</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-2hc4-qjj9-7p6r</link>
      <description>&lt;p&gt;CODESYS Gateway 3 before 3.5.17.0 has a NULL pointer dereference that may result in a denial of service (DoS).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;CODESYS Gateway 3 before 3.5.17.0 has a NULL pointer dereference that may result in a denial of service (DoS).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-2hc4-qjj9-7p6r</guid>
    </item>
    <item>
      <title>gsd-2021-29241</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-29241</link>
      <description>gsd-2021-29241</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-29241</guid>
    </item>
    <item>
      <title>ICSA-25-273-04 — Festo Controller CECC-S,-LK,-D Family Firmware (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-25-273-04</link>
      <description>&lt;p&gt;A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. 3S-Smart Software S…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. 3S-Smart Software S…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-25-273-04</guid>
    </item>
    <item>
      <title>SEVD-2022-011-06 — CODESYS V3 Runtime, Development System, and Gateway Vulnerabilities</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-011-06</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities disclosed by Codesys on CODESYS V3 Runtime, Development System and Gateway. Many vendors, including Schneider Electric,
embed CODESYS in their offers. If successfully exploited, these vulnerabilities could result in denial of service or, in some cases, remote code execution.
Customers should immediately ensure they have implemented cybersecurity best practices across their operations to protect themselves from possible exploitation of these vulnerabilities.
Where appropriate, this includes locating their industrial systems and remotely accessible devices behind firewalls; installing physical controls to prevent unauthorized access; preventing mission-critical systems and devices from being accessed from outside networks; and following
the mitigations and general security recommendations below.
For additional information and support, please contact your Schneider Electric sales or service
representative or Schneider Electric’s Customer Care Center.
March 2023 Update: A remediation is available for HMISTU Series / HMIGTO Series / HMIGTU Series / HMIGTUX Series / HMIGK Series&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities disclosed by Codesys on CODESYS V3 Runtime, Development System and Gateway. Many vendors, including Schneider Electric,
embed CODESYS in their offers. If successfully exploited, these vulnerabilities could result in denial of service or, in some cases, remote code execution.
Customers should immediately ensure they have implemented cybersecurity best practices across their operations to protect themselves from possible exploitation of these vulnerabilities.
Where appropriate, this includes locating their industrial systems and remotely accessible devices behind firewalls; installing physical controls to prevent unauthorized access; preventing mission-critical systems and devices from being accessed from outside networks; and following
the mitigations and general security recommendations below.
For additional information and support, please contact your Schneider Electric sales or service
representative or Schneider Electric’s Customer Care Center.
March 2023 Update: A remediation is available for HMISTU Series / HMIGTO Series / HMIGTU Series / HMIGTUX Series / HMIGK Series&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-011-06</guid>
    </item>
    <item>
      <title>VDE-2021-033 — TRUMPF Laser GmbH: multiple products prone to codesys runtime vulnerabilities</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-033</link>
      <description>&lt;p&gt;The TruControl laser control software (versions 1.04 to 3.0.0) uses CODESYS runtime versions affected by multiple CVEs:&lt;/p&gt;
&lt;p&gt;**CVE list:**&lt;/p&gt;
&lt;p&gt;- CVE-2021-29242
- CVE-2021-29241
- CVE-2019-5105
- CVE-2020-7052
- CVE-2019-9012
- CVE-2019-9010
- CVE-2019-9009
- CVE-2018-10612&lt;/p&gt;
&lt;p&gt;In addition to the CVEs listed above, the affected products are also vulnerable to the following issues without a CVE ID:&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2018-07**&lt;/p&gt;
&lt;p&gt;A crafted communication request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 6.5  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H`&lt;/p&gt;
&lt;p&gt;🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&amp;amp;t=f&amp;amp;f=12928&amp;amp;token=6d1dcea05a15aeef7ad48eadc64c8eca5d4f07b2&amp;amp;download=)&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2018-04**&lt;/p&gt;
&lt;p&gt;The CODESYS runtime system allows access to files outside the restricted working directory of the controller by online services.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 9.9  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H`&lt;/p&gt;
&lt;p&gt;🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&amp;amp;t=f&amp;amp;f=12925&amp;amp;token=50e7240fa947ea215311e3db441f82152f1109b6&amp;amp;download=)&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2017-03**&lt;/p&gt;
&lt;p&gt;A crafted request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 7.5  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:N/…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The TruControl laser control software (versions 1.04 to 3.0.0) uses CODESYS runtime versions affected by multiple CVEs:&lt;/p&gt;
&lt;p&gt;**CVE list:**&lt;/p&gt;
&lt;p&gt;- CVE-2021-29242
- CVE-2021-29241
- CVE-2019-5105
- CVE-2020-7052
- CVE-2019-9012
- CVE-2019-9010
- CVE-2019-9009
- CVE-2018-10612&lt;/p&gt;
&lt;p&gt;In addition to the CVEs listed above, the affected products are also vulnerable to the following issues without a CVE ID:&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2018-07**&lt;/p&gt;
&lt;p&gt;A crafted communication request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 6.5  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H`&lt;/p&gt;
&lt;p&gt;🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&amp;amp;t=f&amp;amp;f=12928&amp;amp;token=6d1dcea05a15aeef7ad48eadc64c8eca5d4f07b2&amp;amp;download=)&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2018-04**&lt;/p&gt;
&lt;p&gt;The CODESYS runtime system allows access to files outside the restricted working directory of the controller by online services.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 9.9  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H`&lt;/p&gt;
&lt;p&gt;🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&amp;amp;t=f&amp;amp;f=12925&amp;amp;token=50e7240fa947ea215311e3db441f82152f1109b6&amp;amp;download=)&lt;/p&gt;
&lt;p&gt;---&lt;/p&gt;
&lt;p&gt;### **CODESYS Advisory 2017-03**&lt;/p&gt;
&lt;p&gt;A crafted request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition.&lt;/p&gt;
&lt;p&gt;- **CVSS v3.0 base score:** 7.5  
- **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:N/…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-033</guid>
    </item>
    <item>
      <title>VDE-2021-054 — Pilz: Multiple vulnerabilities in CODESYS V2 and V3 runtime system</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-054</link>
      <description>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-054</guid>
    </item>
    <item>
      <title>VDE-2022-035 — WAGO: Multiple product series affected by multiple CODESYS vulnerabilities</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2022-035</link>
      <description>&lt;p&gt;Multiple WAGO product families are prone to multiple vulnerabilities affecting CODESYS control runtime system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple WAGO product families are prone to multiple vulnerabilities affecting CODESYS control runtime system.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2022-035</guid>
    </item>
  </channel>
</rss>