      <title>certfr-2022-avi-123 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Elles permettent à un attaquant de provoqu…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2022-avi-123</link>
      <description>certfr-2022-avi-123</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2022-avi-123</guid>
    </item>
    <item>
      <title>EUVD-2026-23150</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-23150</link>
      <description>EUVD-2026-23150</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-23150</guid>
    </item>
    <item>
      <title>fkie_cve-2021-22817</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-22817</link>
      <description>&lt;p&gt;A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-22817</guid>
    </item>
    <item>
      <title>GHSA-qhqr-hrxf-m49q</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-qhqr-hrxf-m49q</link>
      <description>&lt;p&gt;A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-qhqr-hrxf-m49q</guid>
    </item>
    <item>
      <title>gsd-2021-22817</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-22817</link>
      <description>gsd-2021-22817</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-22817</guid>
    </item>
    <item>
      <title>SEVD-2022-039-06 — Harmony/Magelis iPC Series HMI, Vijeo Designer and Vijeo Designer Basic</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2022-039-06</link>
      <description>&lt;p&gt;Schneider Electric is aware of a vulnerability in Harmony/Magelis iPC Series HMI, Vijeo Designer and Vijeo Designer Basic.&#13;
The Harmony/Magelis iPC Series HMI products are configured by Vijeo Designer software.&#13;
Vijeo Designer and Vijeo Designer Basic are software solutions for developing, configuring, and commissioning an entire machine in a single software environment.&#13;
Failure to apply the remediations provided below may risk unauthorized access to the base installation directory due to improper access control lists, which could result in local privilege escalation.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of a vulnerability in Harmony/Magelis iPC Series HMI, Vijeo Designer and Vijeo Designer Basic.&#13;
The Harmony/Magelis iPC Series HMI products are configured by Vijeo Designer software.&#13;
Vijeo Designer and Vijeo Designer Basic are software solutions for developing, configuring, and commissioning an entire machine in a single software environment.&#13;
Failure to apply the remediations provided below may risk unauthorized access to the base installation directory due to improper access control lists, which could result in local privilege escalation.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2022-039-06</guid>