      <title>certfr-2021-avi-443 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2021-avi-443</link>
      <description>certfr-2021-avi-443</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2021-avi-443</guid>
    </item>
    <item>
      <title>EUVD-2026-322733</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-322733</link>
      <description>EUVD-2026-322733</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-322733</guid>
    </item>
    <item>
      <title>fkie_cve-2021-22764</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-22764</link>
      <description>&lt;p&gt;A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-22764</guid>
    </item>
    <item>
      <title>GHSA-57rv-qg24-x8hj</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-57rv-qg24-x8hj</link>
      <description>&lt;p&gt;A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-57rv-qg24-x8hj</guid>
    </item>
    <item>
      <title>gsd-2021-22764</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-22764</link>
      <description>gsd-2021-22764</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-22764</guid>
    </item>
    <item>
      <title>ICSA-24-331-01 — Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-24-331-01</link>
      <description>&lt;p&gt;Overview&#13;
Schneider Electric is aware of a vulnerability in its PowerLogic PM55xx and PowerLogic&#13;
PM8ECC products.&#13;
The PowerLogic PM55xx products are power metering devices. The PowerLogic PM8ECC&#13;
product is an ethernet communication module.&#13;
Failure to apply the mitigations or remediations provided below may risk elevation of privileges,&#13;
which could result in loss of control of the affected device.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Overview&#13;
Schneider Electric is aware of a vulnerability in its PowerLogic PM55xx and PowerLogic&#13;
PM8ECC products.&#13;
The PowerLogic PM55xx products are power metering devices. The PowerLogic PM8ECC&#13;
product is an ethernet communication module.&#13;
Failure to apply the mitigations or remediations provided below may risk elevation of privileges,&#13;
which could result in loss of control of the affected device.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-24-331-01</guid>
    </item>
    <item>
      <title>SEVD-2021-159-02 — PowerLogic PM5500 and PowerLogic PM8ECC</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2021-159-02</link>
      <description>&lt;p&gt;Overview&#13;
Schneider Electric is aware of a vulnerability in its PowerLogic PM55xx and PowerLogic&#13;
PM8ECC products.&#13;
The PowerLogic PM55xx products are power metering devices. The PowerLogic PM8ECC&#13;
product is an ethernet communication module.&#13;
Failure to apply the mitigations or remediations provided below may risk elevation of privileges,&#13;
which could result in loss of control of the affected device.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Overview&#13;
Schneider Electric is aware of a vulnerability in its PowerLogic PM55xx and PowerLogic&#13;
PM8ECC products.&#13;
The PowerLogic PM55xx products are power metering devices. The PowerLogic PM8ECC&#13;
product is an ethernet communication module.&#13;
Failure to apply the mitigations or remediations provided below may risk elevation of privileges,&#13;
which could result in loss of control of the affected device.&lt;/p&gt;</content:encoded>