<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 16 Oct 2026 17:33:37 +0000</lastBuildDate>
    <item>
      <title>bdu:2021-01565</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2021-01565</link>
      <description>bdu:2021-01565</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2021-01565</guid>
    </item>
    <item>
      <title>certfr-2021-avi-175 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Certaines d'entre elles permettent à un at…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2021-avi-175</link>
      <description>certfr-2021-avi-175</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2021-avi-175</guid>
    </item>
    <item>
      <title>cnvd-2021-31178</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2021-31178</link>
      <description>cnvd-2021-31178</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2021-31178</guid>
    </item>
    <item>
      <title>EUVD-2026-23080</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-23080</link>
      <description>EUVD-2026-23080</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-23080</guid>
    </item>
    <item>
      <title>fkie_cve-2021-22712</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2021-22712</link>
      <description>&lt;p&gt;A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2021-22712</guid>
    </item>
    <item>
      <title>GHSA-f9rm-v687-4p23</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-f9rm-v687-4p23</link>
      <description>&lt;p&gt;A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-f9rm-v687-4p23</guid>
    </item>
    <item>
      <title>gsd-2021-22712</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2021-22712</link>
      <description>gsd-2021-22712</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2021-22712</guid>
    </item>
    <item>
      <title>ICSA-21-070-01 — Schneider Electric IGSS SCADA Software</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-21-070-01</link>
      <description>&lt;p&gt;This vulnerability could result in loss of data or remote code execution when a malicious CGF (configuration group file) file is imported into an IGSS Definition.CVE-2021-22709 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in loss of data or remote code execution when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22710 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to missing validation of input data when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22711 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to an unchecked pointer address when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22712 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;This vulnerability could result in loss of data or remote code execution when a malicious CGF (configuration group file) file is imported into an IGSS Definition.CVE-2021-22709 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in loss of data or remote code execution when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22710 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to missing validation of input data when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22711 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to an unchecked pointer address when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22712 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-21-070-01</guid>
    </item>
    <item>
      <title>SEVD-2021-068-01 — IGSS (Interactive Graphical SCADA System)</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2021-068-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the Interactive Graphical SCADA &#13;
System (IGSS) product. &#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling &#13;
industrial processes. IGSS communicates with all major industry standard PLC drivers. &#13;
Failure to apply the remediations provided below may risk remote code execution, which could &#13;
result in an attacker gaining access to the Windows Operating System on the machine used to &#13;
import CGF files, typically a step performed during system design time.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the Interactive Graphical SCADA &#13;
System (IGSS) product. &#13;
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling &#13;
industrial processes. IGSS communicates with all major industry standard PLC drivers. &#13;
Failure to apply the remediations provided below may risk remote code execution, which could &#13;
result in an attacker gaining access to the Windows Operating System on the machine used to &#13;
import CGF files, typically a step performed during system design time.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2021-068-01</guid>
    </item>
  </channel>
</rss>
