<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 07:04:27 +0000</lastBuildDate>
    <item>
      <title>bdu:2021-04322</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2021-04322</link>
      <description>bdu:2021-04322</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2021-04322</guid>
    </item>
    <item>
      <title>certfr-2020-avi-446 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Elles permettent à un attaquant de provoqu…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2020-avi-446</link>
      <description>certfr-2020-avi-446</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2020-avi-446</guid>
    </item>
    <item>
      <title>EUVD-2026-37965</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-37965</link>
      <description>EUVD-2026-37965</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-37965</guid>
    </item>
    <item>
      <title>fkie_cve-2020-7520</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2020-7520</link>
      <description>&lt;p&gt;A CWE-601: URL Redirection to Untrusted Site (&amp;#39;Open Redirect&amp;#39;) vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim&amp;#39;s machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker&amp;#39;s possession. A man-in-the-middle attack is then used to complete the exploit.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-601: URL Redirection to Untrusted Site (&amp;#39;Open Redirect&amp;#39;) vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim&amp;#39;s machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker&amp;#39;s possession. A man-in-the-middle attack is then used to complete the exploit.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2020-7520</guid>
    </item>
    <item>
      <title>GHSA-392j-2p2c-c7m3</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-392j-2p2c-c7m3</link>
      <description>&lt;p&gt;A CWE-601: URL Redirection to Untrusted Site (&amp;#39;Open Redirect&amp;#39;) vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim&amp;#39;s machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker&amp;#39;s possession. A man-in-the-middle attack is then used to complete the exploit.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A CWE-601: URL Redirection to Untrusted Site (&amp;#39;Open Redirect&amp;#39;) vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim&amp;#39;s machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker&amp;#39;s possession. A man-in-the-middle attack is then used to complete the exploit.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-392j-2p2c-c7m3</guid>
    </item>
    <item>
      <title>gsd-2020-7520</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2020-7520</link>
      <description>gsd-2020-7520</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2020-7520</guid>
    </item>
    <item>
      <title>SEVD-2020-196-01 — Schneider Electric Software Update (SESU)</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2020-196-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of a vulnerability in the Schneider Electric Software Update (SESU)&#13;
product.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of a vulnerability in the Schneider Electric Software Update (SESU)&#13;
product.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2020-196-01</guid>
    </item>
  </channel>
</rss>
