<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 13:24:42 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-229035</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-229035</link>
      <description>EUVD-2026-229035</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-229035</guid>
    </item>
    <item>
      <title>fkie_cve-2020-12067</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2020-12067</link>
      <description>&lt;p&gt;In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user&amp;#39;s password may be changed by an attacker without knowledge of the current password.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user&amp;#39;s password may be changed by an attacker without knowledge of the current password.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2020-12067</guid>
    </item>
    <item>
      <title>FSA-202202 — Festo: Controller CECC-S,LK,D family &lt;= 2.3.8.1 - multiple vulnerabilities in CODESYS V3 runtime system</title>
      <link>https://cve.radiocsirt.org/vuln/fsa-202202</link>
      <description>&lt;p&gt;The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The Festo controller CECC product family is affected by multiple vulnerabilities in the CODESYS V3 runtime.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fsa-202202</guid>
    </item>
    <item>
      <title>GHSA-xmxc-2jc7-w66m</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-xmxc-2jc7-w66m</link>
      <description>&lt;p&gt;In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user&amp;#39;s password may be changed by an attacker without knowledge of the current password.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user&amp;#39;s password may be changed by an attacker without knowledge of the current password.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-xmxc-2jc7-w66m</guid>
    </item>
    <item>
      <title>gsd-2020-12067</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2020-12067</link>
      <description>gsd-2020-12067</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2020-12067</guid>
    </item>
    <item>
      <title>ICSA-25-273-04 — Festo Controller CECC-S,-LK,-D Family Firmware (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-25-273-04</link>
      <description>&lt;p&gt;A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. 3S-Smart Software S…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. 3S-Smart Software S…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-25-273-04</guid>
    </item>
    <item>
      <title>VDE-2021-054 — Pilz: Multiple vulnerabilities in CODESYS V2 and V3 runtime system</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2021-054</link>
      <description>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Several Pilz products use Versions V2 and V3 of the CODESYS runtime system from CODESYS GmbH, which enables the execution of IEC 61131-3 PLC programs. These runtime environments contain several vulnerabilities, which an attacker can exploit via the network. Successful exploitation of the vulnerabilities results in reduced availability and, in a worst case, to the insertion of program code.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2021-054</guid>
    </item>
    <item>
      <title>VDE-2022-031 — WAGO: Multiple Products Series affected by multiple CODESYS vulnerabilities</title>
      <link>https://cve.radiocsirt.org/vuln/vde-2022-031</link>
      <description>&lt;p&gt;Multiple WAGO product families are prone to multiple vulnerabilities affecting CODESYS control runtime system.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Multiple WAGO product families are prone to multiple vulnerabilities affecting CODESYS control runtime system.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/vde-2022-031</guid>
    </item>
  </channel>
</rss>