<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sun, 04 Oct 2026 17:24:02 +0000</lastBuildDate>
    <item>
      <title>cnvd-2021-21082</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2021-21082</link>
      <description>cnvd-2021-21082</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2021-21082</guid>
    </item>
    <item>
      <title>EUVD-2026-41044</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-41044</link>
      <description>EUVD-2026-41044</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-41044</guid>
    </item>
    <item>
      <title>fkie_cve-2020-12048</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2020-12048</link>
      <description>&lt;p&gt;Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2020-12048</guid>
    </item>
    <item>
      <title>GHSA-hvxq-9hqc-3fqf</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-hvxq-9hqc-3fqf</link>
      <description>&lt;p&gt;Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-hvxq-9hqc-3fqf</guid>
    </item>
    <item>
      <title>gsd-2020-12048</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2020-12048</link>
      <description>gsd-2020-12048</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2020-12048</guid>
    </item>
    <item>
      <title>ICSMA-20-170-03 — Baxter Phoenix Hemodialysis Delivery System (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-20-170-03</link>
      <description>&lt;p&gt;The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.CVE-2020-12048 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.CVE-2020-12048 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-20-170-03</guid>
    </item>
  </channel>