<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Wed, 07 Oct 2026 16:18:15 +0000</lastBuildDate>
    <item>
      <title>EUVD-2026-49913</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-49913</link>
      <description>EUVD-2026-49913</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-49913</guid>
    </item>
    <item>
      <title>fkie_cve-2019-5024</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2019-5024</link>
      <description>&lt;p&gt;A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2019-5024</guid>
    </item>
    <item>
      <title>GHSA-fcp8-jrh7-67m9</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-fcp8-jrh7-67m9</link>
      <description>&lt;p&gt;A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-fcp8-jrh7-67m9</guid>
    </item>
    <item>
      <title>gsd-2019-5024</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2019-5024</link>
      <description>gsd-2019-5024</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2019-5024</guid>
    </item>
    <item>
      <title>ICSMA-20-196-01 — Capsule Technologies SmartLinx Neuron 2 (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-20-196-01</link>
      <description>&lt;p&gt;A restricted environment escape vulnerability exists in the kiosk mode function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running Version 6.9.1. A specific series of keyboard inputs can allow an escape from the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.CVE-2019-5024 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A restricted environment escape vulnerability exists in the kiosk mode function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running Version 6.9.1. A specific series of keyboard inputs can allow an escape from the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.CVE-2019-5024 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-20-196-01</guid>
    </item>
  </channel>
</rss>
