<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 05 Oct 2026 17:24:53 +0000</lastBuildDate>
    <item>
      <title>cnvd-2019-41423</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2019-41423</link>
      <description>cnvd-2019-41423</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2019-41423</guid>
    </item>
    <item>
      <title>EUVD-2026-241094</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-241094</link>
      <description>EUVD-2026-241094</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-241094</guid>
    </item>
    <item>
      <title>fkie_cve-2019-13543</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2019-13543</link>
      <description>&lt;p&gt;Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2019-13543</guid>
    </item>
    <item>
      <title>GHSA-9c58-qqp7-2wc2</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-9c58-qqp7-2wc2</link>
      <description>&lt;p&gt;Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-9c58-qqp7-2wc2</guid>
    </item>
    <item>
      <title>gsd-2019-13543</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2019-13543</link>
      <description>gsd-2019-13543</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2019-13543</guid>
    </item>
    <item>
      <title>ICSMA-19-311-02 — Medtronic Valleylab FT10 and FX8</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-19-311-02</link>
      <description>&lt;p&gt;The affected products use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.CVE-2019-13543 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). The affected products use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.CVE-2019-13539 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected products use a vulnerable version of the rssh utility in order to facilitate file uploads. This could provide an attacker with administrative access to files or the ability to execute arbitrary code.CVE-2019-3464, and CVE-2019-3463 have been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The affected products use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.CVE-2019-13543 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). The affected products use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.CVE-2019-13539 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected products use a vulnerable version of the rssh utility in order to facilitate file uploads. This could provide an attacker with administrative access to files or the ability to execute arbitrary code.CVE-2019-3464, and CVE-2019-3463 have been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-19-311-02</guid>
    </item>