<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 10 Oct 2026 06:22:31 +0000</lastBuildDate>
    <item>
      <title>bdu:2019-04858</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2019-04858</link>
      <description>bdu:2019-04858</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2019-04858</guid>
    </item>
    <item>
      <title>cnvd-2019-14396</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2019-14396</link>
      <description>cnvd-2019-14396</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2019-14396</guid>
    </item>
    <item>
      <title>EUVD-2026-324273</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-324273</link>
      <description>EUVD-2026-324273</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-324273</guid>
    </item>
    <item>
      <title>fkie_cve-2019-10955</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2019-10955</link>
      <description>&lt;p&gt;In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2019-10955</guid>
    </item>
    <item>
      <title>GHSA-vm5j-x654-r2ww</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-vm5j-x654-r2ww</link>
      <description>&lt;p&gt;In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user?s machine.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user?s machine.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-vm5j-x654-r2ww</guid>
    </item>
    <item>
      <title>gsd-2019-10955</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2019-10955</link>
      <description>gsd-2019-10955</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2019-10955</guid>
    </item>
    <item>
      <title>ICSA-19-113-01 — Rockwell Automation MicroLogix 1400 and CompactLogix 5370 Controllers</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-19-113-01</link>
      <description>&lt;p&gt;An open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user &amp;#39;s machine.CVE-2019-10955 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;An open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user &amp;#39;s machine.CVE-2019-10955 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-19-113-01</guid>
    </item>
  </channel>
</rss>
