<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 02 Oct 2026 23:21:03 +0000</lastBuildDate>
    <item>
      <title>bdu:2018-01158</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2018-01158</link>
      <description>bdu:2018-01158</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2018-01158</guid>
    </item>
    <item>
      <title>certfr-2018-avi-146 — De multiples vulnérabilités ont été découvertes dans SCADA Schneider
Electric Modicon. Certaines d'entre elles permette…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2018-avi-146</link>
      <description>certfr-2018-avi-146</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2018-avi-146</guid>
    </item>
    <item>
      <title>cnvd-2018-06519</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-06519</link>
      <description>cnvd-2018-06519</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-06519</guid>
    </item>
    <item>
      <title>EUVD-2026-63102</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-63102</link>
      <description>EUVD-2026-63102</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-63102</guid>
    </item>
    <item>
      <title>fkie_cve-2018-7242</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-7242</link>
      <description>&lt;p&gt;Vulnerable hash algorithms exists in Schneider Electric&amp;#39;s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Vulnerable hash algorithms exists in Schneider Electric&amp;#39;s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-7242</guid>
    </item>
    <item>
      <title>GHSA-4cgj-crgg-xwgf</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-4cgj-crgg-xwgf</link>
      <description>&lt;p&gt;Vulnerable hash algorithms exists in Schneider Electric&amp;#39;s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Vulnerable hash algorithms exists in Schneider Electric&amp;#39;s Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-4cgj-crgg-xwgf</guid>
    </item>
    <item>
      <title>gsd-2018-7242</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-7242</link>
      <description>gsd-2018-7242</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-7242</guid>
    </item>
    <item>
      <title>ICSA-18-086-01 — Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-18-086-01</link>
      <description>&lt;p&gt;The FTP server does not limit the length of a command parameter which may cause a buffer overflow condition. CVE-2018-7240 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H). The FTP servers contain a hard-coded account, which could allow unauthorized access. CVE-2018-7241 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H). The FTP server does not limit the length of a command parameter, which may cause a buffer overflow condition. CVE-2018-7242 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The FTP server does not limit the length of a command parameter which may cause a buffer overflow condition. CVE-2018-7240 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H). The FTP servers contain a hard-coded account, which could allow unauthorized access. CVE-2018-7241 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H). The FTP server does not limit the length of a command parameter, which may cause a buffer overflow condition. CVE-2018-7242 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-18-086-01</guid>
    </item>
    <item>
      <title>SEVD-2018-081-01 — Embedded FTP Servers for Modicon PAC Controllers</title>
      <link>https://cve.radiocsirt.org/vuln/sevd-2018-081-01</link>
      <description>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the FTP servers of its Modicon PAC controllers.&#13;
&#13;
Modicon PACs (Programmable Automation Controllers) control and monitor industrial operations in a sustainable, flexible, efficient, and protected way. Our PLCs and PACs supply edge technology, augmenting it with Ethernet connectivity, built-in cybersecurity, and processing power needed to handle Big Data analysis and protect against new vulnerabilities among connected industrial assets, across devices or into the cloud.&#13;
&#13;
Failure to address these vulnerabilities could result in unauthorized access to your PLC and a denial of service or other malicious activity.&#13;
&#13;
March 2023 Update: Remediation for the Modicon M580 CPU is available for download&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Schneider Electric is aware of multiple vulnerabilities in the FTP servers of its Modicon PAC controllers.&#13;
&#13;
Modicon PACs (Programmable Automation Controllers) control and monitor industrial operations in a sustainable, flexible, efficient, and protected way. Our PLCs and PACs supply edge technology, augmenting it with Ethernet connectivity, built-in cybersecurity, and processing power needed to handle Big Data analysis and protect against new vulnerabilities among connected industrial assets, across devices or into the cloud.&#13;
&#13;
Failure to address these vulnerabilities could result in unauthorized access to your PLC and a denial of service or other malicious activity.&#13;
&#13;
March 2023 Update: Remediation for the Modicon M580 CPU is available for download&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/sevd-2018-081-01</guid>
    </item>
  </channel>