<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Tue, 06 Oct 2026 13:15:20 +0000</lastBuildDate>
    <item>
      <title>cnvd-2018-02350</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-02350</link>
      <description>cnvd-2018-02350</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-02350</guid>
    </item>
    <item>
      <title>EUVD-2026-62210</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-62210</link>
      <description>EUVD-2026-62210</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-62210</guid>
    </item>
    <item>
      <title>fkie_cve-2018-5438</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-5438</link>
      <description>&lt;p&gt;Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-5438</guid>
    </item>
    <item>
      <title>GHSA-hmpp-gh47-8r55</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-hmpp-gh47-8r55</link>
      <description>&lt;p&gt;Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-hmpp-gh47-8r55</guid>
    </item>
    <item>
      <title>gsd-2018-5438</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-5438</link>
      <description>gsd-2018-5438</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-5438</guid>
    </item>
    <item>
      <title>ICSMA-18-025-01 — Philips IntelliSpace Cardiovascular System Vulnerability</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-18-025-01</link>
      <description>&lt;p&gt;The ISCV application has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The ISCV application has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-18-025-01</guid>