<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 19:39:52 +0000</lastBuildDate>
    <item>
      <title>bdu:2018-00982</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2018-00982</link>
      <description>bdu:2018-00982</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2018-00982</guid>
    </item>
    <item>
      <title>cnvd-2018-19605</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-19605</link>
      <description>cnvd-2018-19605</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-19605</guid>
    </item>
    <item>
      <title>EUVD-2026-240923</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-240923</link>
      <description>EUVD-2026-240923</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-240923</guid>
    </item>
    <item>
      <title>fkie_cve-2018-14781</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-14781</link>
      <description>&lt;p&gt;Medtronic MiniMed MMT&lt;/p&gt;
&lt;p&gt;devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic MiniMed MMT&lt;/p&gt;
&lt;p&gt;devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-14781</guid>
    </item>
    <item>
      <title>GHSA-cv4q-4xgp-cr7m</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-cv4q-4xgp-cr7m</link>
      <description>&lt;p&gt;Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the &amp;#34;easy bolus&amp;#34; and &amp;#34;remote bolus&amp;#34; options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the &amp;#34;easy bolus&amp;#34; and &amp;#34;remote bolus&amp;#34; options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-cv4q-4xgp-cr7m</guid>
    </item>
    <item>
      <title>gsd-2018-14781</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-14781</link>
      <description>gsd-2018-14781</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-14781</guid>
    </item>
    <item>
      <title>ICSMA-18-219-02 — Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsma-18-219-02</link>
      <description>&lt;p&gt;Communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.CVE-2018-10634 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N). The models identified above, when paired with a remote controller and having the easy bolus and remote bolus options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.CVE-2018-14781 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;Communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.CVE-2018-10634 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N). The models identified above, when paired with a remote controller and having the easy bolus and remote bolus options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.CVE-2018-14781 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsma-18-219-02</guid>
    </item>
  </channel>
</rss>
