<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://cve.radiocsirt.org</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 22:14:14 +0000</lastBuildDate>
    <item>
      <title>bdu:2019-00177</title>
      <link>https://cve.radiocsirt.org/vuln/bdu:2019-00177</link>
      <description>bdu:2019-00177</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/bdu:2019-00177</guid>
    </item>
    <item>
      <title>certfr-2018-avi-590 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
      <link>https://cve.radiocsirt.org/vuln/certfr-2018-avi-590</link>
      <description>certfr-2018-avi-590</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/certfr-2018-avi-590</guid>
    </item>
    <item>
      <title>cnvd-2018-25420</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2018-25420</link>
      <description>cnvd-2018-25420</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2018-25420</guid>
    </item>
    <item>
      <title>EUVD-2026-65256</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-65256</link>
      <description>EUVD-2026-65256</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-65256</guid>
    </item>
    <item>
      <title>fkie_cve-2018-11463</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2018-11463</link>
      <description>&lt;p&gt;A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions &amp;lt; V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions &amp;lt; V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions &amp;lt; V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions &amp;lt; V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions &amp;lt; V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions &amp;lt; V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2018-11463</guid>
    </item>
    <item>
      <title>GHSA-82xh-8r83-mpfq</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-82xh-8r83-mpfq</link>
      <description>&lt;p&gt;A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions &amp;lt; V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions &amp;lt; V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions &amp;lt; V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions &amp;lt; V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions &amp;lt; V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions &amp;lt; V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-82xh-8r83-mpfq</guid>
    </item>
    <item>
      <title>gsd-2018-11463</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2018-11463</link>
      <description>gsd-2018-11463</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2018-11463</guid>
    </item>
    <item>
      <title>ICSA-18-345-02 — ICSA-18-345-02 Siemens SINUMERIK Controllers (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-18-345-02</link>
      <description>&lt;p&gt;The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public expl…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public expl…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-18-345-02</guid>
    </item>
  </channel>
</rss>
