    <item>
      <title>cnvd-2017-25723</title>
      <link>https://cve.radiocsirt.org/vuln/cnvd-2017-25723</link>
      <description>cnvd-2017-25723</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/cnvd-2017-25723</guid>
    </item>
    <item>
      <title>EUVD-2026-77285</title>
      <link>https://cve.radiocsirt.org/vuln/euvd-2026-77285</link>
      <description>EUVD-2026-77285</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/euvd-2026-77285</guid>
    </item>
    <item>
      <title>fkie_cve-2017-12718</title>
      <link>https://cve.radiocsirt.org/vuln/fkie_cve-2017-12718</link>
      <description>&lt;p&gt;A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/fkie_cve-2017-12718</guid>
    </item>
    <item>
      <title>GHSA-84pw-5frw-ww2p</title>
      <link>https://cve.radiocsirt.org/vuln/ghsa-84pw-5frw-ww2p</link>
      <description>&lt;p&gt;A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/ghsa-84pw-5frw-ww2p</guid>
    </item>
    <item>
      <title>gsd-2017-12718</title>
      <link>https://cve.radiocsirt.org/vuln/gsd-2017-12718</link>
      <description>gsd-2017-12718</description>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/gsd-2017-12718</guid>
    </item>
    <item>
      <title>ICSA-17-285-04A — NXP Semiconductors MQX RTOS (Update A)</title>
      <link>https://cve.radiocsirt.org/vuln/icsa-17-285-04a</link>
      <description>&lt;p&gt;The Real-Time TCP/IP Communications Suite (RTCS) in MQX &amp;#39;s DHCP client fails to sanitize all inputs, which may allow maliciously crafted DHCP packets to cause memory to be overwritten, allowing remote code execution.CVE-2017-12718 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The DNS client for MQX fails to bounds check DNS response parameters, which may allow maliciously crafted DNS packets to cause memory to be read out-of-bounds, resulting in a denial of service.CVE-2017-12722 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The Real-Time TCP/IP Communications Suite (RTCS) in MQX &amp;#39;s DHCP client fails to sanitize all inputs, which may allow maliciously crafted DHCP packets to cause memory to be overwritten, allowing remote code execution.CVE-2017-12718 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The DNS client for MQX fails to bounds check DNS response parameters, which may allow maliciously crafted DNS packets to cause memory to be read out-of-bounds, resulting in a denial of service.CVE-2017-12722 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://cve.radiocsirt.org/vuln/icsa-17-285-04a</guid>
    </item>