<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-11-17T05:04:54.031549+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cve-2026-93670</id>
    <title>CVE-2026-93670 — Out-of-bounds write in the DesignWare I3C driver when the device address table is full</title>
    <updated>2026-11-17T05:04:54.033644+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> zephyrproject zephyr</p>
<p>The Synopsys DesignWare I3C controller driver (drivers/i3c/i3c_dw.c) tracks free Device Address Table (DAT) slots with get_free_pos(), which signals an exhausted table by returning -1. The helper declared its return type as uint8_t, so the sentinel was truncated to 255, and both consumers (dw_i3c_attach_device() and dw_i3c_i2c_attach_device()) also stored it in a uint8_t before testing if (pos &lt; 0) — a comparison that is never true for an unsigned value. The exhaustion guard was therefore inert in every build.</p>
<p>With the guard defeated, an attach attempted on a full DAT proceeds with pos == 255: it writes data-&gt;dw_i3c_i2c_priv_data[255].id, more than 200 bytes past the end of the 32-element dw_i3c_i2c_priv_data array and past the end of struct dw_i3c_data; it stores the resulting out-of-bounds address in desc-&gt;controller_priv, from which later detach, reattach and IBI operations read the slot index back; and it performs a 32-bit MMIO store 1020 bytes beyond the hardware DAT base, outside the table the controller reports. The attach still returns success, so the upper layer believes the device is bound.</p>
<p>The DAT is smaller than the software array (its depth is read from DEVICE_ADDR_TABLE_POINTER, commonly 8 or 16 entries), so exhaustion is reachable. In a dual-role build (CONFIG_I3C_DUAL_ROLE with CONFIG_I3C_USE_IBI) acting as a secondary controller, the attach count is supplied by the bus's active controller: i3c_sec_handoffed() attaches one device per entry of the received D…</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/cve-2026-93670"/>
  </entry>
</feed>
