<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-07T22:33:24.411290+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-280515</id>
    <title>EUVD-2026-280515</title>
    <updated>2026-10-07T22:33:24.458198+00:00</updated>
    <content>EUVD-2026-280515</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-280515"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2026-34766</id>
    <title>fkie_cve-2026-34766</title>
    <updated>2026-10-07T22:33:24.458236+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8, the select-usb-device event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested filters or was listed in exclusionFilters. The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic. This issue has been patched in versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2026-34766"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-9899-m83m-qhpj</id>
    <title>GHSA-9899-m83m-qhpj — Electron: USB device selection not validated against filtered device list</title>
    <updated>2026-10-07T22:33:24.458280+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> npm: electron</p>
<p>### Impact
The `select-usb-device` event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested `filters` or was listed in `exclusionFilters`.</p>
<p>The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic.</p>
<p>### Workarounds
There are no app side workarounds, you must update to a patched version of Electron.</p>
<p>### Fixed Versions
* `41.0.0-beta.8`
* `40.7.0`
* `39.8.0`
* `38.8.6`</p>
<p>### For more information
If there are any questions or comments about this advisory, send an email to [security@electronjs.org](mailto:security@electronjs.org)</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-9899-m83m-qhpj"/>
  </entry>
</feed>
