  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2025-24582</id>
    <title>cnvd-2025-24582</title>
    <updated>2026-10-07T19:10:38.513483+00:00</updated>
    <content>cnvd-2025-24582</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2025-24582"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-254889</id>
    <title>EUVD-2026-254889</title>
    <updated>2026-10-07T19:10:38.513541+00:00</updated>
    <content>EUVD-2026-254889</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-254889"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-9437</id>
    <title>fkie_cve-2025-9437</title>
    <updated>2026-10-07T19:10:38.513556+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-9437"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-3p4f-g732-2rg3</id>
    <title>GHSA-3p4f-g732-2rg3</title>
    <updated>2026-10-07T19:10:38.513588+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-3p4f-g732-2rg3"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-25-289-04</id>
    <title>ICSA-25-289-04 — Rockwell Automation ArmorStart AOP</title>
    <updated>2026-10-07T19:10:38.513604+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in a denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-25-289-04"/>