<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-16T11:41:11.854514+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-271920</id>
    <title>EUVD-2026-271920</title>
    <updated>2026-10-16T11:41:11.857254+00:00</updated>
    <content>EUVD-2026-271920</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-271920"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-6034</id>
    <title>fkie_cve-2025-6034</title>
    <updated>2026-10-16T11:41:11.857290+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>There is a memory corruption vulnerability due to an out of bounds read in DefaultFontOptions() when using SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.1 and prior versions.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-6034"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-5xq5-7xh5-4jv6</id>
    <title>GHSA-5xq5-7xh5-4jv6</title>
    <updated>2026-10-16T11:41:11.857323+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>There is a memory corruption vulnerability due to an out of bounds read in DefaultFontOptions() when using SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.1 and prior versions.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-5xq5-7xh5-4jv6"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-25-273-06</id>
    <title>ICSA-25-273-06 — National Instruments Circuit Design Suite</title>
    <updated>2026-10-16T11:41:11.857341+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The affected product is vulnerable to a memory corruption of a function table, which could allow an attacker to disclose information or execute arbitrary code. The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-25-273-06"/>
  </entry>