<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-08T14:40:27.194945+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-327689</id>
    <title>EUVD-2026-327689</title>
    <updated>2026-10-08T14:40:27.198259+00:00</updated>
    <content>EUVD-2026-327689</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-327689"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-13036</id>
    <title>fkie_cve-2025-13036</title>
    <updated>2026-10-08T14:40:27.198291+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An authentication
bypass security issue exists within FactoryTalk Historian Site Edition. By
continually sending requests to the login endpoint, an attacker may obtain a
valid authentication token.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-13036"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-q6qc-22qv-jjr8</id>
    <title>GHSA-q6qc-22qv-jjr8</title>
    <updated>2026-10-08T14:40:27.198320+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An authentication
bypass security issue exists within FactoryTalk Historian Site Edition. By
continually sending requests to the login endpoint, an attacker may obtain a
valid authentication token.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-q6qc-22qv-jjr8"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-169-03</id>
    <title>ICSA-26-169-03 — Rockwell Automation FactoryTalk Historian Site Edition</title>
    <updated>2026-10-08T14:40:27.198336+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token. AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service. Depending on the timing of the crash, data present in snapshots/write cache may be lost. AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-169-03"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2026-1982</id>
    <title>WID-SEC-W-2026-1982 — Rockwell Automation FactoryTalk (Historian Site Edition): Mehrere Schwachstellen</title>
    <updated>2026-10-08T14:40:27.198359+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer kann mehrere Schwachstellen in Rockwell Automation FactoryTalk Historian Site Edition ausnutzen, um Sicherheitsvorkehrungen zu umgehen, um einen Denial of Service Angriff durchzuführen, und um Daten zu manipulieren.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2026-1982"/>
  </entry>
</feed>