<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T07:06:05.448894+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2024-11097</id>
    <title>bdu:2024-11097</title>
    <updated>2026-10-03T07:06:05.564393+00:00</updated>
    <content>bdu:2024-11097</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2024-11097"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2024-avi-1062</id>
    <title>certfr-2024-avi-1062 — De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer…</title>
    <updated>2026-10-03T07:06:05.564433+00:00</updated>
    <content>certfr-2024-avi-1062</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2024-avi-1062"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2024-47913</id>
    <title>cnvd-2024-47913</title>
    <updated>2026-10-03T07:06:05.564453+00:00</updated>
    <content>cnvd-2024-47913</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2024-47913"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-262879</id>
    <title>EUVD-2026-262879</title>
    <updated>2026-10-03T07:06:05.564467+00:00</updated>
    <content>EUVD-2026-262879</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-262879"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2024-52051</id>
    <title>fkie_cve-2024-52051</title>
    <updated>2026-10-03T07:06:05.564479+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions &lt; V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions &lt; V19 Update 4), SIMATIC STEP 7 V17 (All versions &lt; V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions &lt; V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions &lt; V19 Update 4), SIMATIC WinCC Unified V17 (All versions &lt; V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions &lt; V19 Update 4), SIMATIC WinCC V17 (All versions &lt; V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions &lt; V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions &lt; V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Clou…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2024-52051"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-x2qg-388q-986c</id>
    <title>GHSA-x2qg-388q-986c</title>
    <updated>2026-10-03T07:06:05.564540+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions), SIMATIC WinCC Unified V17 (All versions), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions), SIMATIC WinCC V17 (All versions), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SIMOTION SCOUT TIA V5.6 SP1 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions). The affected devices do not properly sanit…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-x2qg-388q-986c"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-24-347-02</id>
    <title>ICSA-24-347-02 — Siemens Engineering Platforms</title>
    <updated>2026-10-03T07:06:05.564572+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The affected devices do not properly sanitize  user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-24-347-02"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ssa-392859</id>
    <title>SSA-392859 — SSA-392859: Local Arbitrary Code Execution Vulnerability in Siemens Engineering Platforms before V20</title>
    <updated>2026-10-03T07:06:05.564593+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The affected devices do not properly sanitize  user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ssa-392859"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2024-3656</id>
    <title>WID-SEC-W-2024-3656 — Siemens SIMATIC S7: Mehrere Schwachstellen ermöglichen Codeausführung</title>
    <updated>2026-10-03T07:06:05.564611+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Programmcode auszuführen.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2024-3656"/>
  </entry>
</feed>
