  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2023-avi-1015</id>
    <title>certfr-2023-avi-1015 — De multiples vulnérabilités ont été découvertes dans &lt;span
class="textit"&gt;les produits Siemens&lt;/span&gt;. Certaines d'entr…</title>
    <updated>2026-10-06T15:04:13.237383+00:00</updated>
    <content>certfr-2023-avi-1015</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2023-avi-1015"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2023-97270</id>
    <title>cnvd-2023-97270</title>
    <updated>2026-10-06T15:04:13.237423+00:00</updated>
    <content>cnvd-2023-97270</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2023-97270"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-270605</id>
    <title>EUVD-2026-270605</title>
    <updated>2026-10-06T15:04:13.237439+00:00</updated>
    <content>EUVD-2026-270605</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-270605"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-47374</id>
    <title>fkie_cve-2022-47374</title>
    <updated>2026-10-06T15:04:13.237450+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions &lt; V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.

This could allow an attacker to exhaust system resources and create a denial of service condition for the device.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-47374"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-cr2v-p345-fp24</id>
    <title>GHSA-cr2v-p345-fp24</title>
    <updated>2026-10-06T15:04:13.237503+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions &lt; V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.</p>
<p>This could allow an attacker to exhaust system resources and create a denial of service condition for the device.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-cr2v-p345-fp24"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-47374</id>
    <title>gsd-2022-47374</title>
    <updated>2026-10-06T15:04:13.237526+00:00</updated>
    <content>gsd-2022-47374</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-47374"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-23-348-05</id>
    <title>ICSA-23-348-05 — Siemens SIMATIC and SIPLUS Products</title>
    <updated>2026-10-06T15:04:13.237538+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The affected products do not handle HTTP(S) requests to the web server correctly.

This could allow an attacker to exhaust system resources and create a denial of service condition for the device. The affected products do not handle long file names correctly.

This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-23-348-05"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2023-3101</id>
    <title>WID-SEC-W-2023-3101 — Siemens SIMATIC S7-400 CPU: Mehrere Schwachstellen ermöglichen Denial of Service</title>
    <updated>2026-10-06T15:04:13.237561+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7-400 CPUs ausnutzen, um einen Denial of Service Angriff durchzuführen.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2023-3101"/>
  </entry>