<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-06T19:03:32.940644+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-230832</id>
    <title>EUVD-2026-230832</title>
    <updated>2026-10-06T19:03:32.944847+00:00</updated>
    <content>EUVD-2026-230832</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-230832"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-41627</id>
    <title>fkie_cve-2022-41627</title>
    <updated>2026-10-06T19:03:32.944883+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The physical IoT device of the AliveCor's KardiaMobile, a smartphone-based personal electrocardiogram (EKG) has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient EKG results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphone’s ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-41627"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-4x7m-cpcp-9gfm</id>
    <title>GHSA-4x7m-cpcp-9gfm</title>
    <updated>2026-10-06T19:03:32.944922+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The physical IoT device of the AliveCor's KardiaMobile, a smartphone-based personal electrocardiogram (EKG) has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient EKG results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphone’s ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-4x7m-cpcp-9gfm"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-41627</id>
    <title>gsd-2022-41627</title>
    <updated>2026-10-06T19:03:32.944942+00:00</updated>
    <content>gsd-2022-41627</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-41627"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-22-298-01</id>
    <title>ICSMA-22-298-01 — AliveCor KardiaMobile</title>
    <updated>2026-10-06T19:03:32.944954+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The smartphone application for the affected product is vulnerable to the publicly known Intent Manipulation exploit on Android phones. This exploit allows attackers to bypass app authentication and view or alter information in the app. The physical IoT device of the affected product has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient electrocardiography (EKG) results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphones ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-22-298-01"/>