<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-05T03:49:31.443113+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2022-04260</id>
    <title>bdu:2022-04260</title>
    <updated>2026-10-05T03:49:31.572974+00:00</updated>
    <content>bdu:2022-04260</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2022-04260"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-324144</id>
    <title>EUVD-2026-324144</title>
    <updated>2026-10-05T03:49:31.573012+00:00</updated>
    <content>EUVD-2026-324144</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-324144"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-33971</id>
    <title>fkie_cve-2022-33971</title>
    <updated>2026-10-05T03:49:31.573027+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-33971"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-29r3-8mg2-rxqp</id>
    <title>GHSA-29r3-8mg2-rxqp</title>
    <updated>2026-10-05T03:49:31.573060+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-29r3-8mg2-rxqp"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-33971</id>
    <title>gsd-2022-33971</title>
    <updated>2026-10-05T03:49:31.573079+00:00</updated>
    <content>gsd-2022-33971</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-33971"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-314-07</id>
    <title>ICSA-22-314-07 — Omron NJ/NX-series Machine Automation Controllers</title>
    <updated>2026-10-05T03:49:31.573090+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An attacker who can analyze the communication of the affected product and perform capture-replay can find unintended entry points into the affected product and cause a denial-of-service condition or execute a malicious program.CVE-2022-33971 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-314-07"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/jvndb-2022-002691</id>
    <title>jvndb-2022-002691</title>
    <updated>2026-10-05T03:49:31.573110+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Machine automation controller NJ/NX series, Automation software "Sysmac Studio", and programmable terminal (PT) NA series provided by OMRON Corporation contain multiple vulnerabilities in the communication function.
The vulnerabilities are as follows.

  * Use of Hard-coded Credentials (CWE-798) - CVE-2022-34151
  * Authentication Bypass by Capture-replay (CWE-294) - CVE-2022-33208
  * Active Debug Code (CWE-489) - CVE-2022-33971

OMRON Corporation reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.</p>