<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-07T23:32:27.402706+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-230809</id>
    <title>EUVD-2026-230809</title>
    <updated>2026-10-07T23:32:27.406482+00:00</updated>
    <content>EUVD-2026-230809</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-230809"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-2969</id>
    <title>fkie_cve-2022-2969</title>
    <updated>2026-10-07T23:32:27.406521+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-2969"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-c28m-8g89-fpm5</id>
    <title>GHSA-c28m-8g89-fpm5</title>
    <updated>2026-10-07T23:32:27.406555+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-c28m-8g89-fpm5"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-2969</id>
    <title>gsd-2022-2969</title>
    <updated>2026-10-07T23:32:27.406573+00:00</updated>
    <content>gsd-2022-2969</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-2969"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-307-03</id>
    <title>ICSA-22-307-03 — Delta Industrial Automation DIALink</title>
    <updated>2026-10-07T23:32:27.406585+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The software uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.CVE-2022-2969 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-307-03"/>
  </entry>
</feed>
