<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-12T22:44:36.535073+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2022-02848</id>
    <title>bdu:2022-02848</title>
    <updated>2026-10-12T22:44:36.538498+00:00</updated>
    <content>bdu:2022-02848</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2022-02848"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-188018</id>
    <title>EUVD-2026-188018</title>
    <updated>2026-10-12T22:44:36.538526+00:00</updated>
    <content>EUVD-2026-188018</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-188018"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-28613</id>
    <title>fkie_cve-2022-28613</title>
    <updated>2026-10-12T22:44:36.538540+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-28613"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-9m5v-m5wp-xcm2</id>
    <title>GHSA-9m5v-m5wp-xcm2</title>
    <updated>2026-10-12T22:44:36.538568+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU500 series CMU Firmware 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-9m5v-m5wp-xcm2"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-28613</id>
    <title>gsd-2022-28613</title>
    <updated>2026-10-12T22:44:36.538595+00:00</updated>
    <content>gsd-2022-28613</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-28613"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-242-04</id>
    <title>ICSA-22-242-04 — Hitachi Energy RTU500 series</title>
    <updated>2026-10-12T22:44:36.538606+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the HCI Modbus TCP function included in the affected product versions. If the HCI Modbus TCP is enabled and configured, then an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by a validation error in the length information carried in MBAP header in the HCI Modbus TCP function.CVE-2022-28613 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).</p>