<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-05T10:23:04.157787+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2022-04373</id>
    <title>bdu:2022-04373</title>
    <updated>2026-10-05T10:23:04.164839+00:00</updated>
    <content>bdu:2022-04373</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2022-04373"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2022-avi-628</id>
    <title>certfr-2022-avi-628 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
    <updated>2026-10-05T10:23:04.164883+00:00</updated>
    <content>certfr-2022-avi-628</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2022-avi-628"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-213809</id>
    <title>EUVD-2026-213809</title>
    <updated>2026-10-05T10:23:04.164905+00:00</updated>
    <content>EUVD-2026-213809</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-213809"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-2329</id>
    <title>fkie_cve-2022-2329</title>
    <updated>2026-10-05T10:23:04.164917+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-2329"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-2384-wfr6-9j3j</id>
    <title>GHSA-2384-wfr6-9j3j</title>
    <updated>2026-10-05T10:23:04.164948+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-2384-wfr6-9j3j"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-2329</id>
    <title>gsd-2022-2329</title>
    <updated>2026-10-05T10:23:04.164964+00:00</updated>
    <content>gsd-2022-2329</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-2329"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/sevd-2022-102-01</id>
    <title>SEVD-2022-102-01 — IGSS (Interactive Graphical SCADA System)</title>
    <updated>2026-10-05T10:23:04.164975+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Schneider Electric is aware of a vulnerability in its Data Server module for the IGSS (Interactive Graphical SCADA System) product.
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server is a module with a TCP interface used by other modules to access data of the SCADA System.
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode. July 12, 2022 Update: An additional vulnerability, CVE-2022-2329, was remediated with the released patch.</p>