  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-49913</id>
    <title>EUVD-2026-49913</title>
    <updated>2026-10-06T22:31:08.744278+00:00</updated>
    <content>EUVD-2026-49913</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-49913"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-5024</id>
    <title>fkie_cve-2019-5024</title>
    <updated>2026-10-06T22:31:08.744314+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-5024"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-fcp8-jrh7-67m9</id>
    <title>GHSA-fcp8-jrh7-67m9</title>
    <updated>2026-10-06T22:31:08.744348+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A restricted environment escape vulnerability exists in the “kiosk mode” function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running versions 9.0.3 or lower. A specific series of keyboard inputs can escape the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-fcp8-jrh7-67m9"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-5024</id>
    <title>gsd-2019-5024</title>
    <updated>2026-10-06T22:31:08.744367+00:00</updated>
    <content>gsd-2019-5024</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-5024"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-20-196-01</id>
    <title>ICSMA-20-196-01 — Capsule Technologies SmartLinx Neuron 2 (Update A)</title>
    <updated>2026-10-06T22:31:08.744378+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A restricted environment escape vulnerability exists in the kiosk mode function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running Version 6.9.1. A specific series of keyboard inputs can allow an escape from the restricted environment, resulting in full administrator access to the underlying operating system. An attacker can connect to the device via USB port with a keyboard or other HID device to trigger this vulnerability.CVE-2019-5024 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-20-196-01"/>