  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-324448</id>
    <title>EUVD-2026-324448</title>
    <updated>2026-10-13T00:19:04.975968+00:00</updated>
    <content>EUVD-2026-324448</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-324448"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-25722</id>
    <title>fkie_cve-2019-25722</title>
    <updated>2026-10-13T00:19:04.975998+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-25722"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-fh3f-j952-25x6</id>
    <title>GHSA-fh3f-j952-25x6</title>
    <updated>2026-10-13T00:19:04.976030+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.</p>