    <id>https://cve.radiocsirt.org/vuln/cnvd-2018-08449</id>
    <title>cnvd-2018-08449</title>
    <updated>2026-10-06T12:46:03.765768+00:00</updated>
    <content>cnvd-2018-08449</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2018-08449"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-177245</id>
    <title>EUVD-2026-177245</title>
    <updated>2026-10-06T12:46:03.765813+00:00</updated>
    <content>EUVD-2026-177245</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-177245"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2018-7522</id>
    <title>fkie_cve-2018-7522</title>
    <updated>2026-10-06T12:46:03.765828+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2018-7522"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-293h-57f9-wc4c</id>
    <title>GHSA-293h-57f9-wc4c</title>
    <updated>2026-10-06T12:46:03.765862+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-293h-57f9-wc4c"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2018-7522</id>
    <title>gsd-2018-7522</title>
    <updated>2026-10-06T12:46:03.765880+00:00</updated>
    <content>gsd-2018-7522</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2018-7522"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-18-107-02</id>
    <title>ICSA-18-107-02 — Schneider Electric Triconex Tricon</title>
    <updated>2026-10-06T12:46:03.765891+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>System calls read directly from memory addresses within the control program area without any verification.  Manipulating this data could allow attacker data to be copied anywhere within memory. When a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-18-107-02"/>