  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2018-15734</id>
    <title>cnvd-2018-15734</title>
    <updated>2026-10-04T17:10:25.779227+00:00</updated>
    <content>cnvd-2018-15734</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2018-15734"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-180317</id>
    <title>EUVD-2026-180317</title>
    <updated>2026-10-04T17:10:25.779274+00:00</updated>
    <content>EUVD-2026-180317</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-180317"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2018-14801</id>
    <title>fkie_cve-2018-14801</title>
    <updated>2026-10-04T17:10:25.779289+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2018-14801"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-v52g-8mcm-r52h</id>
    <title>GHSA-v52g-8mcm-r52h</title>
    <updated>2026-10-04T17:10:25.779317+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-v52g-8mcm-r52h"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2018-14801</id>
    <title>gsd-2018-14801</title>
    <updated>2026-10-04T17:10:25.779333+00:00</updated>
    <content>gsd-2018-14801</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2018-14801"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-18-228-01</id>
    <title>ICSMA-18-228-01 — Philips PageWriter TC10, TC20, TC30, TC50, and TC70 Cardiographs (Update A)</title>
    <updated>2026-10-04T17:10:25.779344+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.CVE-2018-14799 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). An attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.CVE-2018-14801 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-18-228-01"/>