  <entry>
    <id>https://cve.radiocsirt.org/vuln/certa-2013-avi-047</id>
    <title>certa-2013-avi-047 — De multiples vulnérabilités ont été corrigées dans &lt;span
class="textit"&gt;Rockwell Automation Controllogix&lt;/span&gt;. Elles…</title>
    <updated>2026-10-18T13:39:44.552210+00:00</updated>
    <content>certa-2013-avi-047</content>
    <link href="https://cve.radiocsirt.org/vuln/certa-2013-avi-047"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-246213</id>
    <title>EUVD-2026-246213</title>
    <updated>2026-10-18T13:39:44.552253+00:00</updated>
    <content>EUVD-2026-246213</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-246213"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2012-6441</id>
    <title>fkie_cve-2012-6441</title>
    <updated>2026-10-18T13:39:44.552269+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP. Successful exploitation of this vulnerability could cause loss of confidentiality.</p>
<p>Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2012-6441"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-qwf3-gf6f-rrw8</id>
    <title>GHSA-qwf3-gf6f-rrw8</title>
    <updated>2026-10-18T13:39:44.552306+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allow remote attackers to obtain sensitive information via a crafted CIP packet.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-qwf3-gf6f-rrw8"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2012-6441</id>
    <title>gsd-2012-6441</title>
    <updated>2026-10-18T13:39:44.552326+00:00</updated>
    <content>gsd-2012-6441</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2012-6441"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-13-011-03</id>
    <title>ICSA-13-011-03 — Rockwell Automation ControlLogix PLC Vulnerabilities</title>
    <updated>2026-10-18T13:39:44.552337+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allow remote attackers to cause a denial of service (control and communication outage) via a CIP message that modifies the (1) configuration or (2) network parameters. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allow remote attackers to cause a denial of service (control and communication outage) via a CIP message that specifies a reset. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENB…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-13-011-03"/>
  </entry>