<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-22T06:55:53.324915+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certa-2012-avi-492</id>
    <title>certa-2012-avi-492 — Une vulnérabilité a été corrigée dans &lt;span
class="textit"&gt;Honeywell&lt;/span&gt;. Elle concerne un débordement de mémoire
ta…</title>
    <updated>2026-10-22T06:55:53.328727+00:00</updated>
    <content>certa-2012-avi-492</content>
    <link href="https://cve.radiocsirt.org/vuln/certa-2012-avi-492"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-166736</id>
    <title>EUVD-2026-166736</title>
    <updated>2026-10-22T06:55:53.328764+00:00</updated>
    <content>EUVD-2026-166736</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-166736"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2012-0254</id>
    <title>fkie_cve-2012-0254</title>
    <updated>2026-10-22T06:55:53.328779+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2012-0254"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-6whg-2qc2-5q4g</id>
    <title>GHSA-6whg-2qc2-5q4g</title>
    <updated>2026-10-22T06:55:53.328815+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-6whg-2qc2-5q4g"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2012-0254</id>
    <title>gsd-2012-0254</title>
    <updated>2026-10-22T06:55:53.328832+00:00</updated>
    <content>gsd-2012-0254</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2012-0254"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-12-150-01</id>
    <title>ICSA-12-150-01 — Honeywell HMIWeb Browser Buffer Overflow Vulnerability</title>
    <updated>2026-10-22T06:55:53.328843+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-12-150-01"/>
  </entry>