    <id>https://cve.radiocsirt.org/vuln/euvd-2026-254910</id>
    <title>EUVD-2026-254910</title>
    <updated>2026-10-02T18:53:51.046090+00:00</updated>
    <content>EUVD-2026-254910</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-254910"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2011-20002</id>
    <title>fkie_cve-2011-20002</title>
    <updated>2026-10-02T18:53:51.046119+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions &lt; V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions &lt; V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2011-20002"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-3p9h-r6fg-7r7h</id>
    <title>GHSA-3p9h-r6fg-7r7h</title>
    <updated>2026-10-02T18:53:51.046154+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions &lt; V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions &lt; V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-3p9h-r6fg-7r7h"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-25-294-03</id>
    <title>ICSA-25-294-03 — Siemens SIMATIC S7-1200 CPU V1/V2 Devices</title>
    <updated>2026-10-02T18:53:51.046174+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-25-294-03"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ssa-625789</id>
    <title>SSA-625789 — SSA-625789: Multiple Vulnerabilities in SIMATIC S7-1200 CPU V1/V2 Devices</title>
    <updated>2026-10-02T18:53:51.046195+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ssa-625789"/>