  <entry>
    <id>https://cve.radiocsirt.org/vuln/cve-2022-2302</id>
    <title>CVE-2022-2302 — LENZE: Missing password verification in authorisation procedure</title>
    <updated>2026-10-06T00:16:42.154698+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> LENZE cabinet c520, LENZE cabinet c550, LENZE cabinet c750</p>
<p>Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/cve-2022-2302"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/vde-2022-030</id>
    <title>VDE-2022-030 — Lenze: Vulnerability in the OPC-UA authentification connection in the firmware</title>
    <updated>2026-10-06T00:16:42.154767+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>The machine controller of the cabinet series include an OPC-UA server which uses an user management to authenticate clients via anonymous or user/password authentication. If the user/password authentication is selected, password verification is skipped upon second login. As a result, cases occur in which users can establish communication without correct authentication. This vulnerability is not located in the OPC-UA protocol or server, but in the interface to the products firmware.</p>
<p>This Security Advisory is only relevant for the following use cases:</p>
<p>• the user management has been activated on the machine controller (is deactivated by default)</p>
<p>• the OPC-UA Server is used</p>
<p>• Data are transferred via a symbol configuration (is not available by default)</p></div>