<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-15T09:41:33.627181+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cve-2022-30312</id>
    <title>CVE-2022-30312</title>
    <updated>2026-10-15T09:41:33.628883+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/cve-2022-30312"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-242-08</id>
    <title>ICSA-22-242-08 — Honeywell Trend Controls Inter-Controller Protocol</title>
    <updated>2026-10-15T09:41:33.628936+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Several Trend Controls IQ Series building automation controllers utilize an Inter-Controller (IC) protocol that uses a 4-digit authentication PIN transmitted in plaintext, allowing usernames and passwords to be transmitted in plaintext when utilizing unsupported legacy versions of the controller. This may allow an attacker with local OT network access to obtain these credentials.CVE-2022-30312 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-242-08"/>
  </entry>
</feed>
