    <id>https://cve.radiocsirt.org/vuln/euvd-2026-321390</id>
    <title>EUVD-2026-321390</title>
    <updated>2026-10-03T20:13:51.524158+00:00</updated>
    <content>EUVD-2026-321390</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-321390"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2026-8479</id>
    <title>fkie_cve-2026-8479</title>
    <updated>2026-10-03T20:13:51.524204+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2026-8479"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-m2rr-g8pf-8wrj</id>
    <title>GHSA-m2rr-g8pf-8wrj</title>
    <updated>2026-10-03T20:13:51.524258+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>IEC 60870-5-104 used in bidirectional mode is vulnerable
for a NULL pointer dereferencing, if a specially crafted
sequence of messages is sent for a certain time, causing
Denial of Service impact.
Product is only affected if IEC 60870-5-104 functionality in
bidirectional mode (BCI) is configured.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-m2rr-g8pf-8wrj"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-155-04</id>
    <title>ICSA-26-155-04 — Hitachi Energy RTU500</title>
    <updated>2026-10-03T20:13:51.524289+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. If exploited, these vulnerabilities primarily impact product availability, with potential secondary impacts on confidentiality and integrity. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-155-04"/>