<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T13:10:45.559113+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-292946</id>
    <title>EUVD-2026-292946</title>
    <updated>2026-10-03T13:10:45.608993+00:00</updated>
    <content>EUVD-2026-292946</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-292946"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2026-39462</id>
    <title>fkie_cve-2026-39462</title>
    <updated>2026-10-03T13:10:45.609031+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2026-39462"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-fvx4-mqf9-ccvh</id>
    <title>GHSA-fvx4-mqf9-ccvh</title>
    <updated>2026-10-03T13:10:45.609071+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-fvx4-mqf9-ccvh"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-111-12</id>
    <title>ICSA-26-111-12 — SenseLive X3050</title>
    <updated>2026-10-03T13:10:45.609093+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability in the X3050's web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions. A vulnerability exists in the X3050's web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased. A vulnerability in the X3050's web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality. A vulnerability exists in the X3050's web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstr…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-111-12"/>