  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2025-12970</id>
    <title>bdu:2025-12970</title>
    <updated>2026-10-02T21:14:38.221239+00:00</updated>
    <content>bdu:2025-12970</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2025-12970"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-249820</id>
    <title>EUVD-2026-249820</title>
    <updated>2026-10-02T21:14:38.221275+00:00</updated>
    <content>EUVD-2026-249820</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-249820"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-7973</id>
    <title>fkie_cve-2025-7973</title>
    <updated>2026-10-02T21:14:38.221290+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-7973"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-r35r-4x8r-v472</id>
    <title>GHSA-r35r-4x8r-v472</title>
    <updated>2026-10-02T21:14:38.221320+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-r35r-4x8r-v472"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-25-226-23</id>
    <title>ICSA-25-226-23 — Rockwell Automation FactoryTalk Viewpoint</title>
    <updated>2026-10-02T21:14:38.221336+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-25-226-23"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2025-1849</id>
    <title>WID-SEC-W-2025-1849 — Rockwell Automation FactoryTalk: Mehrere Schwachstellen</title>
    <updated>2026-10-02T21:14:38.221354+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer kann mehrere Schwachstellen in verschiedenen Rockwell Automation FactoryTalk Komponenten ausnutzen, um Informationen offenzulegen, um Sicherheitsvorkehrungen zu umgehen, und um seine Privilegien zu erhöhen.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2025-1849"/>
  </entry>