<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T02:20:35.957457+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-241992</id>
    <title>EUVD-2026-241992</title>
    <updated>2026-10-03T02:20:35.960440+00:00</updated>
    <content>EUVD-2026-241992</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-241992"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-46352</id>
    <title>fkie_cve-2025-46352</title>
    <updated>2026-10-03T02:20:35.960470+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The CS5000 Fire Panel is vulnerable due to a hard-coded password that 
runs on a VNC server and is visible as a string in the binary 
responsible for running VNC. This password cannot be altered, allowing 
anyone with knowledge of it to gain remote access to the panel. Such 
access could enable an attacker to operate the panel remotely, 
potentially putting the fire panel into a non-functional state and 
causing serious safety issues.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-46352"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-427v-vg76-wcjg</id>
    <title>GHSA-427v-vg76-wcjg</title>
    <updated>2026-10-03T02:20:35.960502+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The CS5000 Fire Panel is vulnerable due to a hard-coded password that 
runs on a VNC server and is visible as a string in the binary 
responsible for running VNC. This password cannot be altered, allowing 
anyone with knowledge of it to gain remote access to the panel. Such 
access could enable an attacker to operate the panel remotely, 
potentially putting the fire panel into a non-functional state and 
causing serious safety issues.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-427v-vg76-wcjg"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-25-148-03</id>
    <title>ICSA-25-148-03 — Consilium Safety CS5000 Fire Panel (Update A)</title>
    <updated>2026-10-03T02:20:35.960520+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited. The CS5000 Fire Panel is vulnerable due to a hard-coded password that runs on a VNC server and is visible as a string in the binary responsible for running VNC. This password cannot be altered, allowing anyone with knowledge of it to gain remote access to the panel. Such access could enable an attacker to operate the panel remotely, potentially putting the fire panel into a non-functional state and causing serious safety issues.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-25-148-03"/>