<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-02T08:59:11.508626+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/3adr011524</id>
    <title>3ADR011524 — AC500 V3 Multiple vulnerabilities</title>
    <updated>2026-10-02T08:59:11.524583+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>ABB became aware of severe vulnerability in the products versions listed as affected in the advisory. An update is available that resolves these vulnerabilities.</p>
<p>An attacker who successfully exploited these vulnerabilities could bypass the user management and read visualization files (CVE-2025-2595), read and write certificates and keys (CVE-2025-41659) or cause a denial-of-service (DoS) (CVE-2025-41691).</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/3adr011524"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/advisory2025-07_vde-2025-051</id>
    <title>Advisory2025-07_VDE-2025-051 — CODESYS Control V3 - Exposed PKI folder</title>
    <updated>2026-10-02T08:59:11.524645+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability in the CODESYS Control runtime system allows low-privileged remote attackers to access the PKI folder via CODESYS protocol, enabling them to read and write certificates and keys. This exposes sensitive cryptographic data and allows unauthorized certificates to be trusted. However, all services remain available, only certificate based encryption and signing features are concerned. The issue affects systems using the optional CmpOpenSSL component for cryptographic operations.</p>
<p>**Update 1.1.0, 01.09.2025:** Updated remediation category - fixed SL runtimes are now available.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/advisory2025-07_vde-2025-051"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2026-00081</id>
    <title>bdu:2026-00081</title>
    <updated>2026-10-02T08:59:11.524673+00:00</updated>
    <content>bdu:2026-00081</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2026-00081"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-248960</id>
    <title>EUVD-2026-248960</title>
    <updated>2026-10-02T08:59:11.524690+00:00</updated>
    <content>EUVD-2026-248960</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-248960"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-41659</id>
    <title>fkie_cve-2025-41659</title>
    <updated>2026-10-02T08:59:11.524701+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-41659"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fsa-202601</id>
    <title>FSA-202601 — Several CODESYS vulnerabilities in Festo Automation Suite</title>
    <updated>2026-10-02T08:59:11.524725+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.</p>
<p>This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.</p>
<p>Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fsa-202601"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-x97q-fjxx-pvxm</id>
    <title>GHSA-x97q-fjxx-pvxm</title>
    <updated>2026-10-02T08:59:11.524829+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-x97q-fjxx-pvxm"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-076-01</id>
    <title>ICSA-26-076-01 — CODESYS in Festo Automation Suite</title>
    <updated>2026-10-02T08:59:11.524845+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently.</p>
<p>This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite.</p>
<p>Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-076-01"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/vde-2026-005</id>
    <title>VDE-2026-005 — ifm: Multiple Vulnerabilities in CR3171</title>
    <updated>2026-10-02T08:59:11.524945+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The Firmware installed on the CR3171 is impacted by various CODESYS vulnerabilities.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/vde-2026-005"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2025-1705</id>
    <title>WID-SEC-W-2025-1705 — CODESYS: Mehrere Schwachstellen</title>
    <updated>2026-10-02T08:59:11.524976+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer kann mehrere Schwachstellen in CODESYS ausnutzen, um einen Denial-of-Service-Zustand auszulösen, Daten zu manipulieren und vertrauliche Informationen preiszugeben.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2025-1705"/>
  </entry>
</feed>
