  <entry>
    <id>https://cve.radiocsirt.org/vuln/7paa020125</id>
    <title>7PAA020125 — Denial of Service Vulnerabilities in System 800xA, Symphony® Plus IEC 61850 communication stack</title>
    <updated>2026-10-02T13:39:11.452131+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>This vulnerability was privately reported relating to ABB’s implementation of the IEC 61850 communication stack for MMS client applications used in some Automation control system products.</p>
<p>Note: IEC 61850 communication typically supports MMS and GOOSE protocols. Some ABB products support both, others only MMS (e.g. S+ Operations and PM 877). In any case, GOOSE communication is not impacted by this reported vulnerability.</p>
<p>If an attacker gains access to a site’s IEC 61850 network, then exploiting this vulnerability will result in a device fault (PM 877, CI850 and CI868 modules) and will require a manual restart.</p>
<p>If this attack is directed at a S+ Operations node running IEC 61850 connectivity, this will result in a crash in the IEC 61850 communication driver which, if continued a repeating basis, will also result in a denial-of-service situation. Note that this does not have an impact on the overall availability and functionality of the S+ Operations node, only the IEC 61850 communication function.</p>
<p>The System 800xA IEC61850 Connect is not affected.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/7paa020125"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-290934</id>
    <title>EUVD-2026-290934</title>
    <updated>2026-10-02T13:39:11.452187+00:00</updated>
    <content>EUVD-2026-290934</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-290934"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-3756</id>
    <title>fkie_cve-2025-3756</title>
    <updated>2026-10-02T13:39:11.452204+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.</p>
<p>The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.</p>
<p>This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-3756"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-h84p-pw6f-c6p6</id>
    <title>GHSA-h84p-pw6f-c6p6</title>
    <updated>2026-10-02T13:39:11.452236+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.</p>
<p>The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.</p>
<p>This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-h84p-pw6f-c6p6"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-120-01</id>
    <title>ICSA-26-120-01 — ABB System 800xA, Symphony Plus IEC 61850</title>
    <updated>2026-10-02T13:39:11.452260+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>This vulnerability was privately reported relating to ABB’s implementation of the IEC 61850 communication stack for MMS client applications used in some Automation control system products.</p>
<p>Note: IEC 61850 communication typically supports MMS and GOOSE protocols. Some ABB products support both, others only MMS (e.g. S+ Operations and PM 877). In any case, GOOSE communication is not impacted by this reported vulnerability.</p>
<p>If an attacker gains access to a site’s IEC 61850 network, then exploiting this vulnerability will result in a device fault (PM 877, CI850 and CI868 modules) and will require a manual restart.</p>
<p>If this attack is directed at a S+ Operations node running IEC 61850 connectivity, this will result in a crash in the IEC 61850 communication driver which, if continued a repeating basis, will also result in a denial-of-service situation. Note that this does not have an impact on the overall availability and functionality of the S+ Operations node, only the IEC 61850 communication function.</p>
<p>The System 800xA IEC61850 Connect is not affected.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-120-01"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2026-1086</id>
    <title>WID-SEC-W-2026-1086 — ABB 800xA CI868 (für AC 800M) und PM877 (Symphony Plus MR): Schwachstelle ermöglicht Denial of Service</title>
    <updated>2026-10-02T13:39:11.452290+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer aus einem angrenzenden Netzwerk kann eine Schwachstelle in ABB 800xA und ABB Symphony Melody ausnutzen, um einen Denial of Service Angriff durchzuführen.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2026-1086"/>
  </entry>