<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T21:45:01.866410+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-266827</id>
    <title>EUVD-2026-266827</title>
    <updated>2026-10-03T21:45:01.870481+00:00</updated>
    <content>EUVD-2026-266827</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-266827"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2025-26386</id>
    <title>fkie_cve-2025-26386</title>
    <updated>2026-10-03T21:45:01.870514+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Johnson Controls iSTAR Configuration Utility (ICU) has Stack-based Buffer Overflow vulnerability. This issue affects iSTAR Configuration Utility (ICU) version 6.9.7 and prior. Successful exploitation of this vulnerability could result in failure within the operating system of the machine hosting the ICU tool.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2025-26386"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-chvq-5q36-924f</id>
    <title>GHSA-chvq-5q36-924f</title>
    <updated>2026-10-03T21:45:01.870546+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Johnson Controls iSTAR Configuration Utility (ICU) has Stack-based Buffer Overflow vulnerability. This issue affects iSTAR Configuration Utility (ICU) version 6.9.7 and prior. Successful exploitation of this vulnerability could result in failure within the operating system of the machine hosting the ICU tool.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-chvq-5q36-924f"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-26-022-04</id>
    <title>ICSA-26-022-04 — Johnson Controls Inc. iSTAR Configuration Utility (ICU) tool</title>
    <updated>2026-10-03T21:45:01.870563+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Under certain circumstances, a successful exploitation of this vulnerability could result in failure within the operating system of the machine hosting the ICU tool.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-26-022-04"/>
  </entry>
</feed>