<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-06T23:47:40.471102+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2024-03951</id>
    <title>bdu:2024-03951</title>
    <updated>2026-10-06T23:47:40.475926+00:00</updated>
    <content>bdu:2024-03951</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2024-03951"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2024-26044</id>
    <title>cnvd-2024-26044</title>
    <updated>2026-10-06T23:47:40.475962+00:00</updated>
    <content>cnvd-2024-26044</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2024-26044"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-2607</id>
    <title>EUVD-2026-2607</title>
    <updated>2026-10-06T23:47:40.475990+00:00</updated>
    <content>EUVD-2026-2607</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-2607"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2024-4609</id>
    <title>fkie_cve-2024-4609</title>
    <updated>2026-10-06T23:47:40.476018+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor could potentially modify and delete the data in a remote database. An attack would only affect the HMI design time, not runtime.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2024-4609"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-qwjm-p7qm-cgm9</id>
    <title>GHSA-qwjm-p7qm-cgm9</title>
    <updated>2026-10-06T23:47:40.476051+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor could potentially modify and delete the data in a remote database. An attack would only affect the HMI design time, not runtime.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-qwjm-p7qm-cgm9"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-24-137-14</id>
    <title>ICSA-24-137-14 — Rockwell Automation FactoryTalk View SE</title>
    <updated>2026-10-06T23:47:40.476069+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the FactoryTalk View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor could potentially modify and delete the data in a remote database. An attack would only affect the HMI design time, not runtime.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-24-137-14"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2024-1119</id>
    <title>WID-SEC-W-2024-1119 — Rockwell Automation FactoryTalk: Mehrere Schwachstellen</title>
    <updated>2026-10-06T23:47:40.476089+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein authentifizierter Angreifer kann mehrere Schwachstellen in Rockwell Automation FactoryTalk ausnutzen, um beliebigen Code auszuführen, Dateien zu manipulieren oder vertrauliche Informationen offenzulegen.</p>