  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2024-01775</id>
    <title>bdu:2024-01775</title>
    <updated>2026-10-08T04:45:13.159131+00:00</updated>
    <content>bdu:2024-01775</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2024-01775"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-200362</id>
    <title>EUVD-2026-200362</title>
    <updated>2026-10-08T04:45:13.159164+00:00</updated>
    <content>EUVD-2026-200362</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-200362"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2023-34347</id>
    <title>fkie_cve-2023-34347</title>
    <updated>2026-10-08T04:45:13.159179+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2023-34347"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-6q78-28qr-rqfx</id>
    <title>GHSA-6q78-28qr-rqfx</title>
    <updated>2026-10-08T04:45:13.159209+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>?Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-6q78-28qr-rqfx"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2023-34347</id>
    <title>gsd-2023-34347</title>
    <updated>2026-10-08T04:45:13.159240+00:00</updated>
    <content>gsd-2023-34347</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2023-34347"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-23-180-01</id>
    <title>ICSA-23-180-01 — Delta Electronics InfraSuite Device Master</title>
    <updated>2026-10-08T04:45:13.159252+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents. Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation. Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code..</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-23-180-01"/>
  </entry>