  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-230815</id>
    <title>EUVD-2026-230815</title>
    <updated>2026-10-07T11:36:58.942480+00:00</updated>
    <content>EUVD-2026-230815</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-230815"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-41629</id>
    <title>fkie_cve-2022-41629</title>
    <updated>2026-10-07T11:36:58.942546+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-41629"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-6rjf-jv9r-jj4v</id>
    <title>GHSA-6rjf-jv9r-jj4v</title>
    <updated>2026-10-07T11:36:58.942580+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-6rjf-jv9r-jj4v"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-41629</id>
    <title>gsd-2022-41629</title>
    <updated>2026-10-07T11:36:58.942599+00:00</updated>
    <content>gsd-2022-41629</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-41629"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-298-07</id>
    <title>ICSA-22-298-07 — Delta Electronics InfraSuite Device Master</title>
    <updated>2026-10-07T11:36:58.942611+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. CVE-2022-41778 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. CVE-2022-38142 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. CVE-2022-41779 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data alr…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-298-07"/>
  </entry>