<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-20T08:11:06.890890+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-230635</id>
    <title>EUVD-2026-230635</title>
    <updated>2026-10-20T08:11:06.894477+00:00</updated>
    <content>EUVD-2026-230635</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-230635"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-3752</id>
    <title>fkie_cve-2022-3752</title>
    <updated>2026-10-20T08:11:06.894512+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic 
loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload 
the user project file to bring the device back online and continue normal operation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-3752"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-q432-7rqq-8cfj</id>
    <title>GHSA-q432-7rqq-8cfj</title>
    <updated>2026-10-20T08:11:06.894545+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic load to cause a denial-of-service condition resulting in a denial-of-service condition. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-q432-7rqq-8cfj"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-3752</id>
    <title>gsd-2022-3752</title>
    <updated>2026-10-20T08:11:06.894564+00:00</updated>
    <content>gsd-2022-3752</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-3752"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-342-03</id>
    <title>ICSA-22-342-03 — Rockwell Automation Logix controllers</title>
    <updated>2026-10-20T08:11:06.894575+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unauthorized user could use a specially crafted sequence of Ethernet and IP messages and combine them with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers, resulting in a denial-of-service condition. If the target device becomes unavailable in this condition, a user would have to clear and redownload the user project file to bring the device back online.CVE-2022-3752 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-342-03"/>
  </entry>
</feed>