  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-222175</id>
    <title>EUVD-2026-222175</title>
    <updated>2026-10-04T20:24:25.576548+00:00</updated>
    <content>EUVD-2026-222175</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-222175"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-3353</id>
    <title>fkie_cve-2022-3353</title>
    <updated>2026-10-04T20:24:25.576622+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.</p>
<p>An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.</p>
<p>Already existing/established client-server connections are not affected.</p>
<p>List of affected CPEs:</p>
<p>*  cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*
  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*
  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2…</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-3353"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-r27w-hfm7-9mc2</id>
    <title>GHSA-r27w-hfm7-9mc2</title>
    <updated>2026-10-04T20:24:25.576678+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections. Already existing/established client-server connections are not affected. List of affected CPEs: * cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:* * cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-r27w-hfm7-9mc2"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-3353</id>
    <title>gsd-2022-3353</title>
    <updated>2026-10-04T20:24:25.576711+00:00</updated>
    <content>gsd-2022-3353</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-3353"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-23-089-01</id>
    <title>ICSA-23-089-01 — Hitachi Energy IEC 61850 MMS-Server (Update B)</title>
    <updated>2026-10-04T20:24:25.576723+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Hitachi Energy is aware of a reported vulnerability in the IEC 61850 communication stack, that is used in the Relion® 670, 650 and SAM600-IO products versions listed in this document. A version is available that remediates the identified vulnerability.
An attacker who successfully exploited this vulnerability could force the IEC 61850 MMS-server communication stack to stop accepting new MMS-client connections. A manual reboot is required to reenable IEC 61850 MMS-server communication for accepting new MMS-client connections. 
During the reboot phase, the primary functionality of the device is not available.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-23-089-01"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/wid-sec-w-2024-2105</id>
    <title>WID-SEC-W-2024-2105 — Hitachi Energy Relion: Mehrere Schwachstellen ermöglichen Denial of Service</title>
    <updated>2026-10-04T20:24:25.576745+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer aus einem angrenzenden Netzwerk oder ein entfernter anonymer Angreifer kann mehrere Schwachstellen in Hitachi Energy Relion ausnutzen, um einen Denial of Service Angriff durchzuführen.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/wid-sec-w-2024-2105"/>
  </entry>