<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-02T23:30:16.516707+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2022-02453</id>
    <title>bdu:2022-02453</title>
    <updated>2026-10-02T23:30:16.616752+00:00</updated>
    <content>bdu:2022-02453</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2022-02453"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2022-avi-123</id>
    <title>certfr-2022-avi-123 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider. Elles permettent à un attaquant de provoqu…</title>
    <updated>2026-10-02T23:30:16.616786+00:00</updated>
    <content>certfr-2022-avi-123</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2022-avi-123"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2022-13066</id>
    <title>cnvd-2022-13066</title>
    <updated>2026-10-02T23:30:16.616806+00:00</updated>
    <content>cnvd-2022-13066</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2022-13066"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-14151</id>
    <title>EUVD-2026-14151</title>
    <updated>2026-10-02T23:30:16.616819+00:00</updated>
    <content>EUVD-2026-14151</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-14151"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-24310</id>
    <title>fkie_cve-2022-24310</title>
    <updated>2026-10-02T23:30:16.616838+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-24310"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-f5c3-fr66-f3j2</id>
    <title>GHSA-f5c3-fr66-f3j2</title>
    <updated>2026-10-02T23:30:16.616899+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-f5c3-fr66-f3j2"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-24310</id>
    <title>gsd-2022-24310</title>
    <updated>2026-10-02T23:30:16.616916+00:00</updated>
    <content>gsd-2022-24310</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-24310"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-046-01</id>
    <title>ICSA-22-046-01 — Schneider Electric IGSS</title>
    <updated>2026-10-02T23:30:16.616926+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages.CVE-2022-24310 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by inserting data at the beginning of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24311 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause modification of an existing file by adding data at the end of the file or creating a new file in the context of the data server. This could potentially lead to remote code execution when an attacker sends a specially crafted message.CVE-2022-24312 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message.CVE-2022-24313 has been assigned to this vulnerability. A CVSS v3 base sco…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-046-01"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/sevd-2022-039-01</id>
    <title>SEVD-2022-039-01 — IGSS (Interactive Graphical SCADA System)</title>
    <updated>2026-10-02T23:30:16.616964+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Schneider Electric is aware of multiple vulnerabilities in the IGSS (Interactive Graphical SCADA
System) Data Server module.
The IGSS product is a state-of-the art SCADA system used for monitoring and controlling
industrial processes. The Data Server is a module with a TCP interface used by other modules
to access data of the SCADA System.
Failure to apply the remediations provided below may risk remote code execution, which could result in a variety of issues including disclosure of data and loss of control of the SCADA System with IGSS running in production mode.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/sevd-2022-039-01"/>
  </entry>
</feed>