  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-230904</id>
    <title>EUVD-2026-230904</title>
    <updated>2026-10-19T15:48:44.660965+00:00</updated>
    <content>EUVD-2026-230904</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-230904"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2022-1797</id>
    <title>fkie_cve-2022-1797</title>
    <updated>2026-10-19T15:48:44.661003+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2022-1797"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-5w24-2pmc-xhp3</id>
    <title>GHSA-5w24-2pmc-xhp3</title>
    <updated>2026-10-19T15:48:44.661047+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-5w24-2pmc-xhp3"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2022-1797</id>
    <title>gsd-2022-1797</title>
    <updated>2026-10-19T15:48:44.661078+00:00</updated>
    <content>gsd-2022-1797</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2022-1797"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-22-144-01</id>
    <title>ICSA-22-144-01 — Rockwell Automation Logix Controllers</title>
    <updated>2026-10-19T15:48:44.661097+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.CVE-2022-1797 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-22-144-01"/>
  </entry>